Column Type Force Sensor LF-602



Range | A | B | C | D | E | F | X | Y | Weight |
50/100/150/200/500kg | 80 | 37.5 | M10*1.5-6H | 74 | 20 | 17 | 60 | 40 |
|
1000/2000/3000kg | 120 | 45 | M20*1.5-6H | 74 | 36 | 30 | 60 | 40 |
|
Capacity | 0--3000kg | Material | Aluminum/Stainless Steel |
Rated Output | 2.0±10%mV/V | Output Impedance | 350± 5Ω |
Zero Balance | ± 2 % F.S. | Insulation | ≥5000MΩ/100VDC |
Non-linearity | 0.05% F.S. | Recommended Excitation | 5-10V |
Hysteresis | 0.05% F.S. | Maximum Excitation | 15V |
Repeatability | 0.05% F.S. | Compensated Temp Range
| - 10 ~ 60℃ |
Creep (30min) | 0.05% F.S. | Operating Temp Range
| - 20 ~ 80 ℃ |
Temp Effect on Output | 0.05% F.S. / 10℃ | Safe Load Limit | 120% |
Temp Effect on Zero
| 0.05% F.S. / 10℃ | Ultimate Load Limit | 200% |
Input Impedance | 385±15Ω | Cable Size | φ 5x 3m |
TEDS |
|